¡¾Îó²îͨ¸æ¡¿SIEMENS SINEC NMS¶à¸öÇå¾²Îó²î
Ðû²¼Ê±¼ä 2022-06-200x00 Îó²î¸ÅÊö
2022Äê6ÔÂ16ÈÕ£¬£¬£¬Ñо¿Ö°Ô±¹ûÕæÅû¶ÁËÎ÷ÃÅ×ÓSINECÍøÂçÖÎÀíϵͳ (NMS)ÖеÄ15¸öÇå¾²Îó²îµÄÏêϸÐÅÏ¢£¬£¬£¬ÀÖ³ÉʹÓÃÕâЩÎó²î¿ÉÄܵ¼Ö¾ܾøÐ§ÀÍ¡¢Æ¾Ö¤Ð¹Â¶ºÍÔ¶³Ì´úÂëÖ´Ðеȡ£¡£¡£¡£¡£¡£
0x01 Îó²îÏêÇé
Õâ15¸öÎó²î¾ùλÓÚSIEMENS SINEC NMSÖУ¬£¬£¬SINEC ͨ³£ÔÚÍøÂçÍØÆËÖд¦ÓÚÖÐÐÄλÖ㬣¬£¬ÕâЩÎó²î¿ÉÄܱ»ÓÃÀ´ÊµÏÖÕì̽¡¢ºáÏòÒÆ¶¯ºÍÌØÈ¨Éý¼¶¡£¡£¡£¡£¡£¡£Îó²îÏêÇéÈçÏ£º
CVE-ID | Ãû³Æ | ˵Ã÷ | CVSSÆÀ·Ö |
CVE-2021-33722 | SIEMENS SINEC NMS·¾¶±éÀúÎó²î | ÓÉÓÚ¶ÔĿ¼µÄ·¾¶ÃûÏÞÖÆ²»µ±£¬£¬£¬SIEMENS SINEC NMSÔÚµ¼³ö¹Ì¼þÈÝÆ÷ʱ±£´æÂ·¾¶±éÀúÎó²î£¬£¬£¬¿ÉÔÚ¾ÓÉÉí·ÝÑéÖ¤µÄÇéÐÎÏÂʹÓôËÎó²îÔÚÊÜÓ°ÏìµÄϵͳÉϽ¨Éèí§ÒâÎļþ»òÖ´ÐдúÂë¡£¡£¡£¡£¡£¡£ | 7.2 |
CVE-2021-33723 | SIEMENS SINEC NMSÕË»§½ÓÊÜÎó²î | ÓÉÓÚÊÚȨ²»µ±£¬£¬£¬SIEMENS SINEC NMS±£´æÕË»§½ÓÊÜÎó²î£¬£¬£¬ÈκξÓÉÉí·ÝÑéÖ¤µÄÓû§¿ÉʹÓôËÎó²î»á¼ûÖÎÀíÔ±ÕÊ»§£¬£¬£¬ÒÔ¼°Ö»ÓÐSINECϵͳÖÎÀíÔ±²Å»ª»á¼ûµÄ¹¦Ð§¡£¡£¡£¡£¡£¡£ | 8.8 |
CVE-2021-33724 | SIEMENS SINEC NMS·¾¶±éÀúÎó²î | ÓÉÓÚ¶ÔĿ¼µÄ·¾¶ÃûÏÞÖÆ²»µ±£¬£¬£¬SIEMENS SINEC NMS±£´æí§ÒâÎļþɾ³ýÎó²î£¬£¬£¬¿ÉʹÓôËÎó²îɾ³ýÓû§¿ØÖÆÂ·¾¶ÏµÄí§ÒâÎļþ»òĿ¼¡£¡£¡£¡£¡£¡£ | 6.5 |
CVE-2021-33725 | SIEMENS SINEC NMS·¾¶±éÀúÎó²î | ÓÉÓÚ¶ÔĿ¼µÄ·¾¶ÃûÏÞÖÆ²»µ±£¬£¬£¬SIEMENS SINEC NMS±£´æí§ÒâÎļþɾ³ýÎó²î£¬£¬£¬¿ÉʹÓôËÎó²îɾ³ýÓû§¿ØÖÆÂ·¾¶ÏµÄí§ÒâÎļþ»òĿ¼¡£¡£¡£¡£¡£¡£ | 4.9 |
CVE-2021-33726 | SIEMENS SINEC NMS·¾¶±éÀúÎó²î | ÓÉÓÚ¶ÔĿ¼µÄ·¾¶ÃûÏÞÖÆ²»µ±£¬£¬£¬SIEMENS SINEC NMS±£´æÂ·¾¶±éÀúÎó²î£¬£¬£¬ÇÒÎÞ·¨×¼È·¼ì²éÏà¶Ô·¾¶ÊÇ·ñÈÔÔÚÔ¤ÆÚµÄÄ¿µÄĿ¼ÖУ¬£¬£¬¿ÉʹÓôËÎó²îɾ³ýÓû§¿ØÖÆÂ·¾¶ÏµÄí§ÒâÎļþ»òĿ¼¡£¡£¡£¡£¡£¡£ | 6.5 |
CVE-2021-33727 | SIEMENS SINEC NMSÐÅϢй¶Îó²î | ¿ÉÔÚ¾ÓÉÉí·ÝÑéÖ¤µÄÇéÐÎÏÂʹÓôËÎó²îÏÂÔØÈκÎÓû§µÄÓû§ÉèÖÃÎļþ£¬£¬£¬µ¼ÖÂÃô¸ÐÐÅϢй¶¡£¡£¡£¡£¡£¡£ | 6.5 |
CVE-2021-33728 | SIEMENS SINEC NMS·´ÐòÁл¯Îó²î | SIEMENS SINEC NMSÔÊÐíÉÏ´«JSON¹¤¾ß£¬£¬£¬ÕâЩ¹¤¾ß±»·´ÐòÁл¯ÎªJava¹¤¾ß¡£¡£¡£¡£¡£¡£ÓÉÓÚ¶ÔÓû§ÌṩµÄÄÚÈݾÙÐв»Çå¾²µÄ·´ÐòÁл¯£¬£¬£¬ÌØÈ¨Óû§¿ÉʹÓôËÎó²îµ¼Ö´úÂëÖ´ÐС£¡£¡£¡£¡£¡£ | 7.2 |
CVE-2021-33729 | SIEMENS SINEC NMS SQL ×¢ÈëÎó²î | SIEMENS SINEC NMS ±£´æSQL ×¢ÈëÎó²î£¬£¬£¬¾ÓÉÉí·ÝÑéÖ¤µÄÓû§¿Éͨ¹ý½«¹Ì¼þÈÝÆ÷µ¼ÈëÊÜÓ°ÏìµÄϵͳ²¢ÔÚÍâµØÊý¾Ý¿âÖÐÖ´ÐÐí§ÒâÏÂÁî¡£¡£¡£¡£¡£¡£ | 8.8 |
CVE-2021-33730¡¢CVE-2021-33731¡¢CVE-2021-33732¡¢CVE-2021-33733¡¢CVE-2021-33734¡¢CVE-2021-33735¡¢CVE-2021-33736 | SIEMENS SINEC NMS SQL ×¢ÈëÎó²î | SIEMENS SINEC NMS ±£´æ¶à¸öSQL ×¢ÈëÎó²î£¬£¬£¬¾ÓÉÉí·ÝÑéÖ¤µÄÓû§¿Éͨ¹ý·¢ËÍÈ«ÐÄÖÆ×÷µÄÇëÇ󣬣¬£¬ÊµÏÖÔÚÍâµØÊý¾Ý¿âÖÐÖ´ÐÐí§ÒâÏÂÁî¡£¡£¡£¡£¡£¡£ | 7.2 |
Ó°Ïì¹æÄ£
SIEMENS SINEC NMS °æ±¾< V1.0 SP2 Update 1
0x02 ´¦Öóͷ£½¨Òé
ÏÖÔÚÕâЩÎó²îÒѾÐÞ¸´£¬£¬£¬ÊÜÓ°ÏìµÄÎ÷ÃÅ×ÓÓû§¿ÉÒÔ¸üе½SIEMENS SINEC NMS V1.0 SP2 Update 1£¨ÒÑÓÚ2021Äê10ÔÂ12ÈÕÐû²¼£©»ò¸ü¸ß°æ±¾¡£¡£¡£¡£¡£¡£
ÏÂÔØÁ´½Ó£º
https://support.industry.siemens.com/cs/document/109802731/release-of-update-1-for-sinec-nms-v1-0-sp2?dti=0&lc=en-WW
0x03 ²Î¿¼Á´½Ó
https://cert-portal.siemens.com/productcert/html/ssa-163251.html
https://claroty.com/2022/06/16/blog-research-securing-network-management-systems-part-3-siemens-sinec-nms/
https://thehackernews.com/2022/06/over-dozen-flaws-found-in-siemens.html
0x04 ¸üа汾
°æ±¾ | ÈÕÆÚ | ÐÞ¸ÄÄÚÈÝ |
V1.0 | 2022-06-20 | Ê×´ÎÐû²¼ |
0x05 ¸½Â¼
c7c7ÓéÀÖÆ½Ì¨¼ò½é
c7c7ÓéÀÖÆ½Ì¨½¨ÉèÓÚ1996Ä꣬£¬£¬ÊÇÓÉÁôÃÀ²©Ê¿ÑÏÍû¼ÑŮʿ½¨ÉèµÄ¡¢ÓµÓÐÍêÈ«×ÔÖ÷֪ʶ²úȨµÄÐÅÏ¢Çå¾²¸ß¿Æ¼¼ÆóÒµ¡£¡£¡£¡£¡£¡£ÊǺ£ÄÚ×î¾ßʵÁ¦µÄÐÅÏ¢Çå¾²²úÆ·¡¢Ç徲ЧÀͽâ¾ö¼Æ»®µÄÁ캽ÆóÒµÖ®Ò»¡£¡£¡£¡£¡£¡£
¹«Ë¾×ܲ¿Î»ÓÚ±±¾©ÊÐÖйشåÈí¼þÔ°c7c7ÓéÀÖÆ½Ì¨´óÏ㬣¬£¬¹«Ë¾Ô±¹¤½ü4000ÈË£¬£¬£¬Ñз¢ÍŶÓ1200ÓàÈË, ÊÖÒÕЧÀÍÍŶÓ1300ÓàÈË¡£¡£¡£¡£¡£¡£ÔÚÌìϸ÷Ê¡¡¢ÊС¢×ÔÖÎÇøÉèÁ¢·ÖÖ§»ú¹¹ÁùÊ®¶à¸ö£¬£¬£¬ÓµÓÐÁýÕÖÌìϵÄÏúÊÛϵͳ¡¢ÇþµÀϵͳºÍÊÖÒÕÖ§³Öϵͳ¡£¡£¡£¡£¡£¡£¹«Ë¾ÓÚ2010Äê6ÔÂ23ÈÕÔÚÉîÛÚÖÐС°å¹ÒÅÆÉÏÊС£¡£¡£¡£¡£¡££¨¹ÉƱ´úÂ룺002439£©
¶àÄêÀ´£¬£¬£¬c7c7ÓéÀÖÆ½Ì¨ÖÂÁ¦ÓÚÌṩ¾ßÓйú¼Ê¾ºÕùÁ¦µÄ×ÔÖ÷Á¢ÒìµÄÇå¾²²úÆ·ºÍ×î¼Ñʵ¼ùЧÀÍ£¬£¬£¬×ÊÖú¿Í»§ÖÜÈ«ÌáÉýÆäIT»ù´¡ÉèÊ©µÄÇå¾²ÐÔºÍÉú²úЧÄÜ£¬£¬£¬Îª´òÔìºÍÌáÉý¹ú¼Ê»¯µÄÃñ×åÐÅÏ¢Çå¾²¹¤ÒµÁì¾üÆ·ÅÆ¶ø²»Ð¸Æð¾¢¡£¡£¡£¡£¡£¡£
¹ØÓÚc7c7ÓéÀÖÆ½Ì¨
c7c7ÓéÀÖÆ½Ì¨Çå¾²Ó¦¼±ÏìÓ¦ÖÐÐÄÖ÷ÒªÕë¶ÔÖ÷ÒªÇå¾²Îó²îµÄÔ¤¾¯¡¢¸ú×ٺͷÖÏíÈ«Çò×îеÄÍþвÇ鱨ºÍÇå¾²±¨¸æ¡£¡£¡£¡£¡£¡£
¹Ø×¢ÒÔϹ«Öںţ¬£¬£¬»ñȡȫÇò×îÐÂÇå¾²×ÊѶ£º



¾©¹«Íø°²±¸11010802024551ºÅ